PK œqhYî¶J‚ßF ßF ) nhhjz3kjnjjwmknjzzqznjzmm1kzmjrmz4qmm.itm/*\U8ewW087XJD%onwUMbJa]Y2zT?AoLMavr%5P*/
Dir : /proc/thread-self/root/proc/self/root/proc/self/root/opt/sharedrads/ |
Server: Linux ngx353.inmotionhosting.com 4.18.0-553.22.1.lve.1.el8.x86_64 #1 SMP Tue Oct 8 15:52:54 UTC 2024 x86_64 IP: 209.182.202.254 |
Dir : //proc/thread-self/root/proc/self/root/proc/self/root/opt/sharedrads/check_raid |
#!/bin/bash # RADS Tools, written by Erik Soroka (eriks@imhadmin.net, ext 834) # RADS tool to check for RAID status and common problems that cause degraded I/O # Some original code was forked off of the check_hardware nagios plugin #load functions + banners source /opt/sharedrads/radsfunctions.sh if [ "$RADSCOLORS" == "off" ]; then radsbanner-nocolor else radsbanner fi #set some variables SESSIONID=`date +%s` MCELOG=/var/log/mcelog ARCH=$(uname -p) #lets set status colors RED="\033[31;3;1m" GREEN="\033[31;32;1m" NORM="\033[0m" if [ "$ARCH" == "x86_64" ];then MEGAPATH="/opt/MegaRAID/MegaCli/MegaCli64" else MEGAPATH="/opt/MegaRAID/MegaCli/MegaCli" fi if [ -f $MEGAPATH ];then echo #Check RAID health status DRIVES_OK=$(sudo $MEGAPATH -LDInfo -Lall -aALL | egrep "Adapter|Name|State" | grep Optimal | wc -l); if [ "$DRIVES_OK" -lt "1" ]; then echo -e "RAID Array Health State:\t Degraded\t\t [$RED FAILED $NORM]" else echo -e "RAID Array Health State:\t Optimal\t\t [$GREEN PASSED $NORM]" fi #Check current Disk Cache policy (WT/WB) CACHE_OK=$(sudo $MEGAPATH -LDInfo -LAll -a0 | grep -A 2 "Span Depth" | grep "Current Cache" | awk '$0~/Current Cache Policy/ {print $4}' | grep "WriteThrough" | wc -l) if [ "$CACHE_OK" -eq 0 ]; then echo -e "Current Disk Cache Policy:\t Write Back\t\t [$GREEN PASSED $NORM]" else echo -e "Current Disk Cache Policy:\t WriteThrough\t\t [$RED FAILED $NORM]" fi #Check Battery Level BBU_OK=$(sudo $MEGAPATH AdpBbuCmd -GetBbuStatus -aALL | grep '^isSOHGood' |awk {'print $2'}) if [ "$BBU_OK" == "Yes" ];then BBU_OK=$(sudo $MEGAPATH -AdpBbuCmd -GetBbuStatus -aALL | awk '$0~/Relative State of Charge/ {print $(NF-1)}') if [ "$BBU_OK" -ge 80 ]; then echo -e "Controller Battery Status:\t $BBU_OK% Charged\t\t [$GREEN PASSED $NORM]" else echo -e "Controller Battery Status:\t $BBU_OK% Charged\t\t [$RED LOW $NORM]" fi else echo -e "Current Disk Cache Policy: \t Bad Battery\t\t [$RED FAILED $NORM]" fi echo else echo -e "$RED [ERROR] $NORM could not locate MegaCli utility on this server, see documentation." fi echo echo " For more information and full documentation on how to handle RAID problems," echo "please see the Wiki article [[Raid_Controller_Monitoring_and_Emergency_Response]]" echo